X-Ray Thickness Gauge
1. X-Ray Thickness Gauge Function
The X-Ray thickness gauge is primarily used for thickness measurement of single material metals and very thin strips. It has the following functions: continuous measurement of the absolute thickness of rolled strip, error curve save and display, equipment failure alarm, transverse section scanning and status detection.
2. Technical Parameters of X-Ray Thickness Gauge
a、 Material :Steel and Stainless Steel Belt;
b、 Thickness :0.01mm~4.0mm;
c、 Width :≤1250 mm;
d、 Rolling Speed:≤1200m/min;
e、 Mobile Mode:Hydraulic;
f、 Measuring Depth:1000mm;
g、 C-frame Opening Height:170mm;
h、 Measurement Accuracy:
l Nonlinear:≤0.15% or ±2μ;
l Response Time:≤0.02s;
l Relationship between Noise and Response Time(with the Thickness Gauges of the World);
Thicknes(mm) | 15ms | 50ms | 100ms | 250ms |
0 | ±2.7μm | ±1.5μm | ±1.0μm | ±0.7μm |
1 | ±0.4% | ±0.25% | ±0.16% | ±0.1% |
2 | ±0.3% | ±0.20% | ±0.15% | ±0.1% |
l Zero Drift:≤±0.002mm/8h.
3. X-Ray Thickness Gauge Composition
a、 C Type Measuring Body Unit;
b、 Left and Right Magnification Processing Units ;
c、 Computer Detection Processing Unit;
d、 Cooling Unit;
e、 Trailer and Mobile Unit.